{"id":9148,"date":"2016-02-05T15:42:59","date_gmt":"2016-02-05T07:42:59","guid":{"rendered":"http:\/\/localhost\/help\/?page_id=9148"},"modified":"2018-02-12T10:10:33","modified_gmt":"2018-02-12T02:10:33","slug":"server-release-4-3-2","status":"publish","type":"page","link":"https:\/\/oihelp.corporate.ifs.com\/help\/p2-server\/server-releases\/server-release-4-3-2\/","title":{"rendered":"Server Release 4.3.2"},"content":{"rendered":"\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-1222\" src=\"https:\/\/oihelp.corporate.ifs.com\/help\/wp-content\/uploads\/2015\/02\/P2_RGB-Server-Icon.png\" alt=\"P2_RGB Server Icon\" width=\"112\" height=\"129\" srcset=\"https:\/\/oihelp.corporate.ifs.com\/help\/wp-content\/uploads\/2015\/02\/P2_RGB-Server-Icon.png 248w, https:\/\/oihelp.corporate.ifs.com\/help\/wp-content\/uploads\/2015\/02\/P2_RGB-Server-Icon-130x150.png 130w, https:\/\/oihelp.corporate.ifs.com\/help\/wp-content\/uploads\/2015\/02\/P2_RGB-Server-Icon-21x24.png 21w, https:\/\/oihelp.corporate.ifs.com\/help\/wp-content\/uploads\/2015\/02\/P2_RGB-Server-Icon-31x36.png 31w, https:\/\/oihelp.corporate.ifs.com\/help\/wp-content\/uploads\/2015\/02\/P2_RGB-Server-Icon-42x48.png 42w\" sizes=\"auto, (max-width: 112px) 100vw, 112px\" \/><\/p>\n<p class=\"intro-text\">Release 4.3.2 adds the full set of calculations previously available in version 2.6.<\/p>\n<p class=\"intro-text\">The Proficy adaptor is also included in this release, as well as an adaptor for retrieving data from P2 Explorer 2.6.<\/p>\n<p class=\"intro-text\">\u00a0<\/p>\n<p style=\"border-bottom: 1px solid #aaa;\">\u00a0<\/p>\n<h3 class=\"page-subheading\">Proficy Adaptor<\/h3>\n<p class=\"intro-text\">The Proficy Adaptor connects to the GE Proficy Historian and provides the ability to read and write time series tag data to and from the historian. Note that the adaptor requires as a prerequisite, the Proficy Historian Client Tools that match the version of the historian installed.<\/p>\n<p class=\"intro-text\">The Proficy Adaptor supports versions 4.5 and 5.5 of the Proficy Historian and provides the following configuration parameters:<\/p>\n<ul class=\"intro-text\">\n<li>Request timeout<\/li>\n<li>Use Proficy reliable session<\/li>\n<li>Server certificate validation mode<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<hr \/>\n<h3 class=\"page-subheading\">P2 Server 2.6 Adaptor<\/h3>\n<p class=\"intro-text\">The P2 Server 2.6 Adaptor connects to the P2 Explorer 2.6 data dictionary and provides the provides the ability to fetch tag data from datasources already configured in P2 Explorer 2.6. Note that the adaptor requires as a prerequisite, the P2 Explorer 2.6 SDK Client (matching the version of the SDK server you want to connect to).<\/p>\n<p class=\"intro-text\">The P2 Server 2.6 Adaptor provides following configuration parameters:<\/p>\n<ul class=\"intro-text\">\n<li>Included datasources<\/li>\n<li>Excluded datasources<\/li>\n<li>Configured portal protocol<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<hr \/>\n<h3 class=\"page-subheading\">Tag Discovery Prefix<\/h3>\n<p class=\"intro-text\">In v4.3.2 tags can be assigned a prefix as they are fetched from a tag datasource. This can be configured in P2 Server Management Studio, when configuring the datasource.<\/p>\n<p class=\"intro-text\">The prefix is optional and will only apply to tags that are fetched after the prefix has been specified. Changing the prefix will not update existing tags, but will be added to new tags that are fetched from that datasource.<\/p>\n<p><a href=\"https:\/\/oihelp.corporate.ifs.com\/help\/wp-content\/uploads\/2016\/02\/tag-prefix.png\" rel=\"attachment wp-att-9149 lightbox-0\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-large wp-image-9149\" src=\"https:\/\/oihelp.corporate.ifs.com\/help\/wp-content\/uploads\/2016\/02\/tag-prefix-800x436.png\" alt=\"tag prefix\" width=\"800\" height=\"436\" \/><\/a><\/p>\n<p>&nbsp;<\/p>\n<hr \/>\n<h3 class=\"page-subheading\">Calculations<\/h3>\n<p class=\"intro-text\">All calculations previously available in P2 Explorer 2.6 are now available in P2 Server 4.3.2.<\/p>\n<p class=\"intro-text\">Most of the functions retain the same name and syntax, but some have been renamed or changed slightly. The summary of changes is as follows:<\/p>\n<table>\n<thead>\n<tr style=\"border: 1px solid #cccccc;\">\n<td style=\"padding-left: 5px;\" width=\"178\"><strong>v2.6<\/strong><\/td>\n<td width=\"441\"><strong>v4.3<\/strong><\/td>\n<\/tr>\n<\/thead>\n<tbody>\n<tr style=\"border: 1px solid #cccccc;\">\n<td style=\"padding-left: 5px;\" width=\"178\">ACCUM<\/td>\n<td width=\"441\">Renamed to Sum_Sampled<\/td>\n<\/tr>\n<tr style=\"border: 1px solid #cccccc;\">\n<td style=\"padding-left: 5px;\" width=\"178\">AVG<\/td>\n<td width=\"441\">Renamed to Average<\/td>\n<\/tr>\n<tr style=\"border: 1px solid #cccccc;\">\n<td style=\"padding-left: 5px;\" width=\"178\">HIST_AVERAGE<\/td>\n<td width=\"441\">Renamed to Average_Sampled<\/td>\n<\/tr>\n<tr style=\"border: 1px solid #cccccc;\">\n<td style=\"padding-left: 5px;\" width=\"178\">HIST_CONTINUOUSMAX<\/td>\n<td width=\"441\">Renamed to ContinuousMax_Sampled<\/td>\n<\/tr>\n<tr style=\"border: 1px solid #cccccc;\">\n<td style=\"padding-left: 5px;\" width=\"178\">Hist_ContinuousMin<\/td>\n<td width=\"441\">Renamed to ContinuousMin_Sampled<\/td>\n<\/tr>\n<tr style=\"border: 1px solid #cccccc;\">\n<td style=\"padding-left: 5px;\" width=\"178\">HIST_MAX<\/td>\n<td width=\"441\">Renamed to Max_Sampled<\/td>\n<\/tr>\n<tr style=\"border: 1px solid #cccccc;\">\n<td style=\"padding-left: 5px;\" width=\"178\">HIST_Min<\/td>\n<td width=\"441\">Renamed to Min_Sampled<\/td>\n<\/tr>\n<tr style=\"border: 1px solid #cccccc;\">\n<td style=\"padding-left: 5px;\" width=\"178\">HIST_TIMEWEIGHTEDAVERAGE<\/td>\n<td width=\"441\">Renamed to TimeWeightedAverage_Sampled<\/td>\n<\/tr>\n<tr style=\"border: 1px solid #cccccc;\">\n<td style=\"padding-left: 5px;\" width=\"178\">INTEGRAL<\/td>\n<td width=\"441\">Renamed to SampledIntegral<\/td>\n<\/tr>\n<tr style=\"border: 1px solid #cccccc;\">\n<td style=\"padding-left: 5px;\" width=\"178\">MOD<\/td>\n<td width=\"441\">Replaced by the % operator.<\/td>\n<\/tr>\n<tr style=\"border: 1px solid #cccccc;\">\n<td style=\"padding-left: 5px;\" width=\"178\">NUMSAMPLES<\/td>\n<td width=\"441\">Renamed to Count_Sampled.<\/td>\n<\/tr>\n<tr style=\"border: 1px solid #cccccc;\">\n<td style=\"padding-left: 5px;\" width=\"178\">POWER<\/td>\n<td width=\"441\">Replaced by the ** operator.<\/td>\n<\/tr>\n<tr style=\"border: 1px solid #cccccc;\">\n<td style=\"padding-left: 5px;\" width=\"178\">VALUEAT<\/td>\n<td width=\"441\">Renamed to ValueAt_Sampled.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p class=\"intro-text\"><strong>Syntax changes<\/strong><\/p>\n<ul class=\"intro-text\">\n<li><strong>Use of brackets<\/strong>\n<p class=\"intro-text\">In v2.6, if a function did not take any parameters, it could be called without brackets.<br \/>\n However in v4.3.2, all function calls must use brackets. Only keywords can be used without the brackets. Available keywords are:<\/p>\n<p class=\"intro-text code-fragment\">E, ENTITY, FALSE, Log10E, Log2E, NULL, PI, SYSTEMTIME, TRUE.<\/p>\n<\/li>\n<li><strong>Data types<\/strong><br \/>\n In v2.6 all data was either a string or a double. v4.3.2 has more data types available. A printable \u201ccheat sheet\u201d is available in the Explorer Help Center, showing how expressions containing various data types will resolve using the Calculation Engine.<\/li>\n<li><strong>Sampling()<\/strong>\n<p class=\"intro-text\">In v2.6, the SAMPLING() function calls accepted an empty string or a single space for the sample method if the sample method was not going to be changed. <br \/>\n In v4.3.2, an empty string cannot be used. Instead, you should use param[sampleMethod] within the expression, which will look up the current sample method being used. Examples include:<\/p>\n<p class=\"intro-text code-fragment\">SAMPLING(EXPR, param[sampleMethod], 3600)<br \/>\n SAMPLING(EXPR, param[sampleMethod], {du\u201900:01:00:00})<br \/>\n SAMPLING(EXPR, \u201cLastKnownValue\u201d, param[sampleInterval])<\/p>\n<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<hr \/>\n<h3 class=\"page-subheading\">Time Zones<\/h3>\n<p class=\"intro-text\">Two new time zone settings have been added to the configuration utility: <strong>CalendarTimeZone<\/strong> and <strong>ProductionTimeZone<\/strong>.<\/p>\n<ul class=\"intro-text\">\n<li>CalendarTimeZone can be overridden inside a calculation.<\/li>\n<li>ProductionTimeZone will not be able to be overridden.<\/li>\n<\/ul>\n<p class=\"intro-text\">Note that converting time between local time and UTC is still the responsibility of the consuming application. We recommend the use of a time zone picker to control this conversion, which will be important in order to choose how to view production data across time zones.<\/p>\n<p>&nbsp;<\/p>\n<hr \/>\n<h2 class=\"page-subheading\">Previous Releases<\/h2>\n<ul class=\"intro-text\">\n<li><a href=\"https:\/\/oihelp.corporate.ifs.com\/help\/p2-server\/server-release-4-3-1\/\">Server 4.3.1<\/a><\/li>\n<li><a href=\"https:\/\/oihelp.corporate.ifs.com\/help\/p2-server\/server-release-4-3-0\/\">Server 4.3.0<\/a><\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>Release 4.3.2 adds the full set of calculations previously available in version 2.6. The Proficy adaptor is also included in this release, as well as an adaptor for retrieving data from P2 Explorer 2.6.<\/p>\n<p class=\"continue-reading-button\"> <a class=\"continue-reading-link\" href=\"https:\/\/oihelp.corporate.ifs.com\/help\/p2-server\/server-releases\/server-release-4-3-2\/\">Read more<i class=\"crycon-right-dir\"><\/i><\/a><\/p>\n","protected":false},"author":1,"featured_media":9150,"parent":28839,"menu_order":26,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":"","_members_access_role":[],"_members_access_error":""},"categories":[7],"tags":[],"class_list":["post-9148","page","type-page","status-publish","has-post-thumbnail","hentry","category-release-notes","Product-srv"],"_links":{"self":[{"href":"https:\/\/oihelp.corporate.ifs.com\/help\/wp-json\/wp\/v2\/pages\/9148","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/oihelp.corporate.ifs.com\/help\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/oihelp.corporate.ifs.com\/help\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/oihelp.corporate.ifs.com\/help\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/oihelp.corporate.ifs.com\/help\/wp-json\/wp\/v2\/comments?post=9148"}],"version-history":[{"count":0,"href":"https:\/\/oihelp.corporate.ifs.com\/help\/wp-json\/wp\/v2\/pages\/9148\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/oihelp.corporate.ifs.com\/help\/wp-json\/wp\/v2\/pages\/28839"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/oihelp.corporate.ifs.com\/help\/wp-json\/wp\/v2\/media\/9150"}],"wp:attachment":[{"href":"https:\/\/oihelp.corporate.ifs.com\/help\/wp-json\/wp\/v2\/media?parent=9148"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/oihelp.corporate.ifs.com\/help\/wp-json\/wp\/v2\/categories?post=9148"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/oihelp.corporate.ifs.com\/help\/wp-json\/wp\/v2\/tags?post=9148"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}